    Sensor for Distance Measurement Using Pixel Grey-Level Information

    TitleSensor for Distance Measurement Using Pixel Grey-Level Information
    Publication TypeJournal Article
    Año de publicación2009
    AutoresLazaro, JL, Cano, A, Fernández, PR, Pompa, Y
    Idioma de publicaciónEnglish
    JournalSensors
    Volumen9
    Número11
    Páginas8896
    Fecha de publicación8906
    Rank in category11/56
    JCR CategoryInstruments & Instrumentation
    JCR Impact Factor1.870
    ISSN1424-8220
    URLhttp://www.mdpi.com/1424-8220/9/11/8896/
    DOI10.3390/s91108896
    Abstract

    An alternative method for distance measurement is presented, based on a radiometric approach to the image formation process. The proposed methodology uses images from an infrared emitting diode (IRED) to estimate the distance between the camera and the IRED. Camera output grey-level intensities are a function of the accumulated image irradiance, which is also related by inverse distance square law to the distance between the camera and the IRED. Analyzing camera-IRED distance, magnitudes that affected image grey-level intensities, and therefore accumulated image irradiance, were integrated into a differential model which was calibrated and used for distance estimation over a 200 to 600 cm range. In a preliminary model, the camera and the emitter were aligned.